高级检索   注册
SEMI OpenIR  > 中国科学院半导体研究所(2009年前)  > 期刊论文

题名: An improved TM method for full two-port calibration of the asymmetric test fixtures
作者: Zhu NH;  Liu C;  Pun EYB;  Chung PS
发表日期: 2005
摘要: Three known standards, including at least one transmission standard, are normally required for the full two-port calibration of test fixtures. Based on the triple-through method, a new general-purpose calibration procedure using only one known reflection standard is proposed in this paper. The experimental results show that our method call provide a simple and accurate approach to fall two-port calibration of the asymmetric test fixtures. (c) 2005 Wiley Periodicals, Inc.
KOS主题词: Calibration
刊名: MICROWAVE AND OPTICAL TECHNOLOGY LETTERS
专题: 中国科学院半导体研究所(2009年前)_期刊论文

条目包含的文件

文件 大小格式
2663.pdf100KbAdobe PDF 联系获取全文


许可声明:条目相关作品遵循知识共享协议(Creative Commons)。


推荐引用方式:
Zhu, NH; Liu, C; Pun, EYB; Chung, PS .An improved TM method for full two-port calibration of the asymmetric test fixtures ,MICROWAVE AND OPTICAL TECHNOLOGY LETTERS,JUN 5 2005,45 (5):438-441
个性服务