Knowledge Management System Of Institute of Semiconductors,CAS
Thermal analysis and test for single concentrator solar cells | |
Cui Min; Chen Nuofu; Yang Xiaoli![]() ![]() ![]() | |
2009 | |
Source Publication | 半导体学报
![]() |
Volume | 30Issue:4Pages:61-64 |
Abstract | A thermal model for concentrator solar cells based on energy conservation principles was designed. Under 400X concentration with no cooling aid, the cell temperature would get up to about 1200℃.Metal plates were used as heat sinks for cooling the system, which remarkably reduce the cell temperature. For a fixed concentration ratio, the cell temperature reduced as the heat sink area increased. In order to keep the cell at a constant temperature, the heat sink area needs to increase linearly as a function of the concentration ratio. GaInP/GaAs/Ge triple-junction solar cells were fabricated to verify the model. A cell temperature of 37℃ was measured when using a heat sink at 400X concentratration. |
metadata_83 | institute of semiconductors, chinese academy of sciences |
Subject Area | 半导体材料 |
Indexed By | CSCD |
Language | 英语 |
CSCD ID | CSCD:3543900 |
Date Available | 2010-11-23 |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://ir.semi.ac.cn/handle/172111/15807 |
Collection | 中国科学院半导体研究所(2009年前) |
Recommended Citation GB/T 7714 | Cui Min,Chen Nuofu,Yang Xiaoli,et al. Thermal analysis and test for single concentrator solar cells[J]. 半导体学报,2009,30(4):61-64. |
APA | Cui Min,Chen Nuofu,Yang Xiaoli,Wang Yu,Bai Yining,&Zhang Xingwang.(2009).Thermal analysis and test for single concentrator solar cells.半导体学报,30(4),61-64. |
MLA | Cui Min,et al."Thermal analysis and test for single concentrator solar cells".半导体学报 30.4(2009):61-64. |
Files in This Item: | ||||||
File Name/Size | DocType | Version | Access | License | ||
3728.pdf(399KB) | 限制开放 | -- | Application Full Text |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment