Tolerance analysis for incident angle of volume phase holographic grating used in optical channel performance monitor
Xin HL; Li F; Cao P; He YJ; Chen P; Liu YL; Xin HL Chinese Acad Sci Inst Semicond Res & Dev Ctr Optoelect POB 912 Beijing 100083 Peoples R China.
2004
会议名称3rd International Symposium on Instrumentation Science and Technology
会议录名称PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3
页码31-35
会议日期AUG 18-22, 2004
会议地点Xian, PEOPLES R CHINA
出版地16 FUXINGJIE NANGANGQU, HARBIN 150006, HEILONGJIANG, PEOPLES R CHINA
出版者HARBIN INSTITUTE TECHNOLOGY PUBLISHERS
ISBN7-5603-2056-2
部门归属chinese acad sci, inst semicond, res & dev ctr optoelect, beijing 100083, peoples r china
摘要Transmission Volume Phase Holographic Grating (VPHG) is adopted as spectral element in the real-time Optical Channel Performance Monitor (OCPM), which is in dire need in the Dense Wavelength -division-multiplexing(DATDM) system. And the tolerance of incident angle, which can be fully determined by two angles: 6 and (p, is finally inferred in this paper. Commonly, the default setting is that the incident plane is perpendicular to the fringes when the incident angle is mentioned. Now the situation out of the vertical is discussed. By combining the theoretic analysis of VPHG with its use in OCPM and changing 6 and (0 precisely in the computation and experiment, the two physical quantities which can fully specify the performance of VPHG the diffraction efficiency and the resolution, are analyzed. The results show that the diffraction efficiency varies greatly with the change of 6 or (p. But from the view of the whole C-band, only the peak diffraction efficiency drifts to another wavelength. As for the resolution, it deteriorates more rapidly than diffraction efficiency with the change of (p, while more slowly with the change of theta. Only if \phi\less than or equal to+/-1degrees and alpha(B) -0.5 less than or equal to theta less than or equal to alpha(B) + 0.5, the performance of the VPHG would be good enough to be used in OCPM system.
关键词Ocpm Vphg Incident Angle Tolerance
学科领域半导体器件
主办者Int Comm Measurements & Instrumentat.; Natl Nat Sci Fdn China.; Chinese Soc Measurement.; China Instrument Soc.; Harbin Inst Technol.; Instrumentat Comm CSM.; Xian Jiaotong Univ.
收录类别CPCI-S
语种英语
文献类型会议论文
条目标识符http://ir.semi.ac.cn/handle/172111/13585
专题中国科学院半导体研究所(2009年前)
通讯作者Xin HL Chinese Acad Sci Inst Semicond Res & Dev Ctr Optoelect POB 912 Beijing 100083 Peoples R China.
推荐引用方式
GB/T 7714
Xin HL,Li F,Cao P,et al. Tolerance analysis for incident angle of volume phase holographic grating used in optical channel performance monitor[C]. 16 FUXINGJIE NANGANGQU, HARBIN 150006, HEILONGJIANG, PEOPLES R CHINA:HARBIN INSTITUTE TECHNOLOGY PUBLISHERS,2004:31-35.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
2776.pdf(571KB) 限制开放--请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xin HL]的文章
[Li F]的文章
[Cao P]的文章
百度学术
百度学术中相似的文章
[Xin HL]的文章
[Li F]的文章
[Cao P]的文章
必应学术
必应学术中相似的文章
[Xin HL]的文章
[Li F]的文章
[Cao P]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。